Causes and solutions of negative pressure in FRP storage tank

2016-07-27

For more information about the purchase of FRP storage tanks, please click the name at the top of the article.

During the use of the water treatment equipment of the FRP tank, if the high-pressure pump of the reverse osmosis equipment absorbs water directly from the filter tank, or there is a height difference between the position of the FRP tank and the emptying point when the system is evacuated, a negative pressure will be formed. Because the maximum negative pressure that the FRP tank can bear is 127mmhg, if it exceeds the bearing range, the shoulder of the FRP tank will be broken or flattened.

Zaoqiang Shuangli FRP storage tank

The main reason for these phenomena is that there is continuous or short-term negative pressure in these equipment during operation, and the equipment is not equipped with anti negative pressure valve. After many times of transient negative pressure for a long time, the FRP tank will appear delamination, which will eventually lead to shoulder fracture.

What are the reasons for the negative pressure in the FRP storage tank? Here are some common situations:

1、 The water produced from the FRP tank (sand, carbon and soft) directly enters the RO pump. When the equipment is running, the raw water pump and RO pump stop at the same time, and there is negative pressure in the FRP tank, especially when the operating pressure is low (less than 1kg), it is easy to have instantaneous negative pressure.

Solution: pay attention to the shutdown sequence of raw water pump and RO pump, and remember not to shut down at the same time.

Vertical FRP storage tank

2、 The water production pipe of FRP tank is long or lower than the height of FRP tank. When the equipment is running, the raw water pump suddenly stops, which is easy to produce negative pressure.

Solution: pay close attention to the operation of the equipment and adjust the length of the water production pipe in time.

3、 When the equipment is switched between backwashing, washing and operation, if the blowdown pipe is long and lower than the height of FRP tank, it is also easy to produce negative pressure.

4、 Negative pressure will often occur due to misoperation of operators.

Solution: the operator must operate according to the operating procedures and shall not change the operating method at will.

Horizontal FRP storage tank

In addition to the above situations, there are other reasons that will also lead to the negative pressure of FRP tank. I won't cite them one by one here. In the process of actual use of FRP tank, we should pay attention to the above situations at any time. Once found, it should be solved in time to prevent negative pressure from affecting the use of FRP tank.